Installation

Firebox Installation

Install the firebox in one of the

following methods:

Within a new or existing

mantel. refer to Figure 1 for

minimum dimension requirements.

Within a new wall

construction.

New Wall Construction

select a suitable location that

is not susceptible to moisture and

is away from drapes, furniture and

high traffic.

Place the fireplace in the

desired location to see how it will

look in the room.

mark the desired location on

the floor and store the fireplace in

a safe, dry and dust free location.

Use studs to frame an

opening of 24 ½ inches (622 mm)

wide X 18 ¼ inches (463.6 mm)

high X 9 inches (229 mm) deep.

Choose a wiring method:

Option #1 - The power cord can

be led from behind the trim

and along the wall to an outlet

near the fireplace.

Option #2 - A new outlet can be

installed inside the new frame

construction. Plug the unit into

a 15 Amp / 120 volt outlet. If

the cord does not reach, you

may use an extension cord

rated for a minimum of 1875

Watts.

Option #3 - hardwire
refer to hardwire installation

instructions on page 8.

Final Steps
Carefully pour and evenly

distribute the supplied glass

rock media on the front tray of

the firebox (Figure 5). once

complete, hang the front glass

assembly on the mounts of the

firebox.

Figure 5

Front glass

Mounts

hooks

Advertising