Installation – Dimplex DFG2562SS User Manual

Page 8

Advertising
background image

8

www.dimplex.com

Installation

Hardwire option
The firebox comes packaged with

a two (2) prong power cord but

allows for an easy conversion for

hardwired installations. Follow

the steps below to hardwire your

firebox.

Wire a dedicated, properly

fused circuit with a 120 volt,

15 Amp rating. Allow up to

eight (8) feet of service cable

for connecting power supply to

junction box on firebox when

installing.

Figure 1

A - 9” (229 mm)
b - 24 ½” (622 mm)
C - 18 ¼” (463.6 mm)

A

b

C

CAUTION: Use two (2)

conductor, non-metallic sheath

cable with ground wire (3 wires

total) for the incoming power

supply on fireplace inserts.

Use appropriate wire to meet

local and national electrical

codes for rated power

consumption.

remove the outer jacket and

strip the individual conductor from

the end.

Loosen the screw securing

the junction box cover and

remove the cover.

Take the cables out from the

junction box, loosen the two wire

twist nuts and remove the cord

set (Figure 2).

Figure 2

Advertising