RC3000 Antenna Controller

Chapter 3

Detailed Operation

89

3.2.2.8 Settings

The SETTINGS mode provides a way to change the operational characteristics of the RC3000 without
having to go to the configuration group of screens. It also provides a way to reset a drive error without
going to the DRIVE RESET maintenance screen.

1-AUTOPEAK:OFF SETTINGS

2- AP SIG:SS1

<0>RESET DRIVE

<1-2>CHANGE SETTING <MODE>MENU

<0>RESET

DRIVE

This selection is only available if an azimuth, elevation or polarization drive error (jam or runaway) is
active. Selecting 0 will attempt to clear the error.

1-AUTOPEAK:
AUTOPEAK <0>DISABLE <1>ENABLE <2>+PEAK

Selection 0 allows the user to disable the autopeak function (OFF).

Selection 1 allows the user to turn the basic autopeak function on (ON).

Selection 2 allows the user to enable the terminal peakup function (ON+) described in 3.2.2.3.5. NOTE:
Verify that the required conditions for terminal peakup as described in 3.2.2.3.5 are present before
selecting this option.

2-AP SIG:
SIGNAL SOURCE <1>RF <2>SS1 <3>SS2

Selection 2 allows the user to change the signal source that will be used with the autopeak function.

Advertising