Mdt2, Water seal – Scotsman MDT2 User Manual

Page 26

Advertising
background image

WATER SEAL

Stationary Half

1. Insert new water seal into bottom of evaporator.

2. Insert new bearing under the water seal, push or
tap both in until the bottom of the bearing is flush

3. Assemble adapter to evaporator. Tightening the
mounting bolts will correctly position the bottom
bearing and bottom seal.

Rotating Half

1. Remove old rotating half from the auger. Clean
the mounting area.

2. Place a bead of food grade sealant (such as
Scotsman part number 19-0529-01) onto the
shoulder of the auger where the rotating half of the
water seal will be installed.

3. Wash the new seal in water. While wet, slip it
onto the bottom of the auger, rubber side toward
the auger. Push up until seated against the
sealant. Do not allow any sealant to come into
contact with the face of the seal.

MDT2

May 2002

Page 26

Bottom of

Auger

Advertising