Sce170, Service diagnosis – Scotsman SCE170 User Manual

Page 21

Advertising
background image

SYMPTOM

POSSIBLE CAUSE

PROBABLE FIX

Machine operates, no ice is
formed.

Unit stuck in harvest cycle.

Check for curtain stuck closed.

Cubes too small, adjust bridge
thickness, see Cube Size/Bridge
thickness section

Refrigerant leak

Locate leak, repair, replace dryer,
evacuate and weigh in nameplate
charge

Compressor will not operate

Check compressor contactor coil.

Check compressor.

Check compressor start circuit

Hot gas valve stuck open.

Replace hot gas valve.

Refrigerant leak.

Locate leak, repair, replace dryer,
evacuate and weigh in nameplate
charge.

Hot gas valve and purge valve
stay on after curtains close and
both curtain indicator lights are on.

Replace control board.

Purge valve leaks thru.

Clean or replace purge valve

Compressor cycles on and off.

Compressor overheats.

Low on refrigerant. Repair leak,

evacuate and weigh in nameplate
charge

Air cooled - fan not blowing,
repair fan.

TXV not letting enough refrigerant
into evaporators, replace TXV.

Mechanical fault with compressor,
replace compressor.

Check start capacitor

Check start relay

Frost on compressor

Some frost will not hurt.

Do nothing.

TXV meters too much refrigerant.

Replace TXV.

To check bin control system:

When curtain is closed, BOTH
curtain indicator lights on the
control board in the control box
should be ON, if not:

Curtain not closed properly

Check action of curtains

Sensor not in correct position

Place sensor assembly in correct
position

Curtain missing

Replace curtain

Curtain sensor has failed.

Replace sensor assembly.

Service Diagnosis

SCE170

October 1998

Page 21