Refrigeration System Service: HP62 (R-404A)

VAPOR VAPOR
TEMP. PRESSURE TEMP. PRESSURE
(DEG F)

(PSIG) (DEG F) (PSIG)

-20 . . . . . . 17

70 . . . . . . . 146

-18 . . . . . . 18

72 . . . . . . . 150

-16 . . . . . . 20

74 . . . . . . . 155

-14 . . . . . . 21

76 . . . . . . . 161

-12 . . . . . . 23

78 . . . . . . . 166

-10 . . . . . . 24

80 . . . . . . . 171

-8 . . . . . . . 26

82 . . . . . . . 177

-6 . . . . . . . 28

84 . . . . . . . 182

-4 . . . . . . . 29

86 . . . . . . . 188

-2 . . . . . . . 31

88 . . . . . . . 194

0 . . . . . . . 33

90 . . . . . . . 200

2 . . . . . . . 35

92 . . . . . . . 206

4 . . . . . . . 37

94 . . . . . . . 212

6 . . . . . . . 39

96 . . . . . . . 219

8 . . . . . . . 41

98 . . . . . . . 225

10 . . . . . . . 43

100 . . . . . . 232

12 . . . . . . . 46

102 . . . . . . 239

14 . . . . . . . 48

104 . . . . . . 246

16 . . . . . . . 50

106 . . . . . . 253

18 . . . . . . . 53

108 . . . . . . 260

20 . . . . . . . 55

110 . . . . . . 268

22 . . . . . . . 58

112 . . . . . . 275

24 . . . . . . . 60

114 . . . . . . 283

26 . . . . . . . 63

116 . . . . . . 291

28 . . . . . . . 66

118 . . . . . . 299

30 . . . . . . . 69

120 . . . . . . 307

32 . . . . . . . 72

122 . . . . . . 316

34 . . . . . . . 75

124 . . . . . . 324

36 . . . . . . . 78

126 . . . . . . 333

38 . . . . . . . 81

128 . . . . . . 342

40 . . . . . . . 85

130 . . . . . . 351

42 . . . . . . . 88

132 . . . . . . 360

44 . . . . . . . 91

134 . . . . . . 370

46 . . . . . . . 95

136 . . . . . . 379

48 . . . . . . . 99

138 . . . . . . 389

50 . . . . . . . 102

140 . . . . . . 399

52 . . . . . . . 106

142 . . . . . . 409

54 . . . . . . . 110

144 . . . . . . 420

56 . . . . . . . 114

146 . . . . . . 430

58 . . . . . . . 118

148 . . . . . . 441

60 . . . . . . . 123

150 . . . . . . 452

62 . . . . . . . 127

152 . . . . . . 464

64 . . . . . . . 132

154 . . . . . . 475

66 . . . . . . . 136

156 . . . . . . 487

68 . . . . . . . 141

158 . . . . . . 499

Pressure-Temperature Chart for HP62

This ice machine uses R-404A refrigerant and
polyolester oil. Do NOT use mineral oil in this
refrigeration system.

R-404A is a "Near Azeotrope" so liquid
charging is required:

¤

Weigh in as liquid as much of the charge as
possible into the discharge line.

¤

Install a sight glass between the manifold and
the suction side hose and carefully meter
liquid into the suction side, using the manifold
valve to "flash off" the liquid before it enters
the ice machine. Do this until the proper
amount of refrigerant has been weighed into
the system.

When the system is serviced, a special liquid
line drier is required. It is included with
replacement compressors.

HP62 is not compatable with mineral oil, so
these ice machines use Polyolester oil.
Polyolester oil absorbs water very easily. When
one of these refrigeration systems is opened for
service, it must be re-sealed as soon as
possible (15 minutes maximum).

Special leak detection equipment is required to
locate small refrigerant leaks. Usually a leak
detector capable of dectecting a Halongenated
refrigerant or HFC-134A will work. Check with
the leak detector manufacturer if in doubt.