Sce170, Installation, For the electrician – Scotsman SCE170 User Manual

Page 6: After utility connections, Final check list

Advertising
background image

Installation

For The Electrician

This is a cord-connected unit, and must be on a
separate 115 volt AC 60 cycle single phase power
supply. The maximum fuse size for this circuit
should be 15 amps, per the nameplate use fuses,
or HACR circuit breakers.

Follow All Local Codes - This Unit Must Be
Grounded.
Do not use extension cords and do not
disable or by-pass ground prong on electrical plug.

After Utility Connections:

1. Level the cabinet, use the leg levelers on the
end of the legs to adjust the cabinet height. (Legs
should have been installed when the unit was
unpacked).

2. Wash out the bin and hood. If desired, the
interior of the bin could be sanitized.

3. Locate the scoop, wash it and have it available
for use when needed.

Final Check List

1. Is the ice maker cabinet in a room where
ambient temperatures are within the minimum and
maximum temperatures specified?

2. Has the water supply been connected?

3. Is the water pressure adequate?

4. Have the water connections been checked for
water leaks?

5. Have the drain connections been made?

6. Have the drain connections been checked for
leaks?

7. Is the cabinet level?

8. Is the ice machine plugged into a 115 volt
electrical power supply and is the ice machine the
only load on that circuit?

9. Has all of the shipping material been removed
from the inside of the cabinet?

10. Has the bin and cabinet been wiped clean and
sanitized?

11. Has the Customer Evaluation & Warranty
Registration form been filled out? Check for correct
model and serial numbers from the nameplate,
then mail the completed form to Scotsman.

12. Has the owner/user been given the name and
telephone number of the authorized Scotsman
Service Agency serving that location?

13. To start up machine, follow the directions on
page 10. For more information on the unit, turn to
the next page.

SCE170

October 1998

Page 6