ADDENDUM

Page 7 of 8

KM OPERATING MANUAL

KM 700 BOARD ADDENDUM CONTINUED

13.14 REV 3/20/06

OUT4 (Output 4 Settings)

There are 3 standard outputs, 1 safety output and one accessory output on your Skutt KilnMaster controller.
The accessory output is designated as Output 4 and can control a number of optional accessories including
vents, alarms and autodialers. Output 4 will cycle these accessories on and off at different times depending
on the program you are running and the way you configure it under the “OUT4” feature setting. There are
5 different options for OUT4.

Note: “ALR4” is the factory default setting. When you access the Output 4 feature the feature options will
appear in the order listed below. The first option listed is not necessarily the current setting.

“OP A” (Option A)
When option A is selected Output 4 will turn on when a ConeFire Mode program is started. When the
program has run and the kiln has cooled to 150 °F output 4 will turn off.

When a Ramp/Hold program is entered it will ask whether you want the fan (or other accessory) on for
each segment you program. After you enter the hold time for each segment the display will show “FAN”
along with the number of the segment you are programming. Alternately it will flash the current setting,
either “OFF” or “ON”. To change the setting toggle it with the “1” key and press “ENTER” to select that
setting.

“OP b” (Option B)
During a ConeFire program Output 4 will turn on when “START” is pressed. It will then turn off at 1450
°F. It will turn back on when the kiln is cooling and the temperature drops below 1000 °F. It will then turn
off when the kiln cools to 150 °F.

When a Ramp/Hold program is entered it will ask whether you want the fan (or other accessory) on for
each segment you program. After you enter the hold time for each segment the display will show “FAN”
along with the number of the segment you are programming. Alternately it will flash the current setting,
either “OFF” or “ON”. To change the setting toggle it with the “1” key and press “ENTER” to select that
setting.

“OP C” (Option C)
When Option C is selected Output 4 does not come on during any portion of a ConeFire Mode program.
When a Ramp/Hold program is entered it will ask whether you want the fan (or other accessory) on for
each segment you program. After you enter the hold time for each segment the display will show “FAN”
along with the number of the segment you are programming. Alternately it will flash the current setting,
either “OFF” or “ON”. To change the setting toggle it with the “1” key and press “ENTER” to select that
setting.

“ALR4” (Alarm 4)
This is the factory default setting. If Output 4 is not being utilized this is the setting that should be selected.
This feature can also control an external alarm or autodialer to initiate if an Error Code is generated or if
the internal temperature of the kiln reaches the temperature programmed for the ALARM setting of the
program. To deactivate the alarm press “ENTER”.

“PCT” (Percent On)
Output 4 can be programmed to be on for a percent of the time output 2 is on. This option is used when
output 4 controls floor or lid elements. To ensure output 4 stays off at all times, use this option and set the
percentage to zero. The percent can be set from 0 to 150. There are currently no Skutt Kiln designs that can
utilize this feature.