3 system installation, Hub installation – SP Controls AmpLINC System User Manual

Page 8

Advertising
background image

8

3 System Installation

CAUTION: Before installing your system, make sure that
you have read the Important Safety Precautions at the
beginning of this manual.

3.1. Hub Installation

The AmpLINC Hub is a UL 2043 plenum-rated unit which can be
safely installed in the plenum space. SP Controls recommends
that the unit is secured in some fashion to prevent movement of
the unit if one of the cables is pulled during installation of an am-
plifier node.

For full UL 2043 (Plenum) compliance, the external power supply
should be placed in an area other than a plenum space.

3.1.1 Input Connections

The AmpLINC Hub accepts an unbalanced stereo input using
either RCA or 3.5mm plugs. The standard wiring is shown below.

13

4.2.2 Indicators and Controls on AmpLINC Puck

Each AmpLINC Puck has an amber LED on top which will illumi-
nate when power is supplied to the from the Hub.

Note - When the AmpLINC Hub is in sleep mode, the amber LED
indicators on the top of the Pucks will turn off.


To control the wattage of the amplifier Puck, refer to section

3.2.2.

Advertising