Model 771 confi guration—reference level – Studio Technologies 761 User Manual

Page 24

Advertising
background image

Issue 1, March 2008

Model 761/771 User Guide

Page 24

Studio Technologies, Inc.

for Surround

Default:

Reference level set for fully attenuated (minimum) monitor output level.

Note:

The 5-second delay is a safety feature ensuring that the reference level will not be accidently changed.

To permanently store the new value, you must still exit the confi guration mode.

Model 771 Confi guration—Reference Level

Press and hold the Reference Level button for 5 seconds to take a
“snapshot” of the level control’s setting at the time confi guration mode
was entered. The Reference Level LED will fl ash when the button is
initially pressed and then light solid when the “snapshot” has been taken.