Fc100 - floating point fast fourier transform – Sundance FC100 v.2.3 User Manual

Page 16

Advertising
background image

FC100 - Floating Point Fast Fourier Transform

v2.3

Fast Fourier Transform product manual

October 2005

www.sundance.com

- 16 -

Continuous processing between two consecutive passes

Figure 6 : empty_pipeline low


When a pass transition occurs, the din_bank and dout_bank signals are inverted.
However, due to the core latency, the dout_bank signal is inverted after the din_bank
signal, when all the data for the previous pass have been processed through the core.
Forcing the empty_pipeline signal low when starting the core will enable to continuously
process data through the core without pausing between two consecutive passes. As a
result the core will need to access the same memory bank for read and write operations
simultaneously. Therefore, if this mode is used, the processing memory banks connected
to the core must be dual port.