To Change Process Setpoint:

When the device is in AUTO Mode and in Normal Display Mode

q

Press the

⇑⇑

or

⇓⇓

for more than 2 seconds, and the set point will begin changing.

q

After achieving the desired set point, the instrument will time out for 2 seconds, and
flash the new setting, indicating it has accepted the change.

To Change to CO Factor (When Instrument is in Carbon Control Mode):

When the device is in AUTO MODE and in Normal Display Mode

q

Press the MENU button – (Gr. 1 will be displayed in Yellow)

q

Press FUNC Button twice - This will display COF in the bottom window and the
value in the middle window (Set Point Window)

q

Adjust the parameter by using

⇑⇑

or

⇓⇓

key

q

After achieving the desired value, you must press the FUNC button once again for
the change to be accepted.

q

The instrument will time out for 30 seconds and return to Normal Display Mode or
you may press the MENU button several times until you return to Normal Display
Mode

q

To Verify that your change was accepted you may view the COF by pressing the
FUNC button until you reach COF in the lower Display.

To Change to H

2

F Factor (When Instrument is in Dewpoint Control Mode):

When the device is in AUTO MODE and in Normal Display Mode

q

Press the MENU button – (Gr. 1 will be displayed in Yellow)

q

Press FUNC Button three times - This will display H

2

F in the bottom window and the

value in the middle window (Set Point Window)

q

Adjust the parameter by using

⇑⇑

or

⇓⇓

key

q

After achieving the desired value, you must press the FUNC button once again for
the change to be accepted.

q

The instrument will time out for 30 seconds and return to Normal Display Mode or
you may press the MENU button several times until you return to Normal Display
Mode