SECTION 5 SPECIFICATIONS

ELECTRICAL:
Supply Voltage: 120 AC Single Phase
Ambient Temperature:

0°C to +40°C

Fuses:

2 x 1 A 20mm Quick Blow

Relay Outputs:

Pump Relay: 3A single pole
Aux. Relay: 3A single pole changeover

MECHANICAL:
Dimensions:

SMT 100 Unit:

Width: 165mm
Height: 100mm
Depth: 85mm

Sensor:

diameter: 7.3mm (8.5mm
for heat shrink)

Weight:

SMT 100 Unit:

0.96Kg

Box Material:

Plastic

SENSORS:
Type:

SX

TM

PT 100 Platinum Film

Compensation:

3 wire compensated

PARTS LIST

SMT 100 Unit

C0132

SX PT100 Sensor Assembly: 25m Collector

A0741

SX PT100 Sensor Assembly: 10m Collector

A7143

SX PT100 Sensor Assembly: 5m Tank

A0742

SX PT100 Sensor Assembly: 5m Return

A7141

SX PT100 Sensor Assembly: 0.5m Return

A0740

SX Sensor Extender 10m

A6911

SX Sensor Extender 20m

A6921

SX Sensor Extender 50m

A6951

External relay 16A

C0328

CE

This product has been tested to the EU EMC 89/336/EEC directive according to the
Manufacturers report, which is available upon request.

This product is in conformance with the Low Voltage Directive 73/23/EEC.

Thermomax certifies that this datalogging and / or control device has been
manufactured to an ISO 9002 Quality System.

Thermomax undertakes to repair or replace the device, if same is shown to be
defective in its manufacture and / or components, but Thermomax shall not be
responsible for any other financial or economic loss (or any indirect loss) which may
be incurred by the buyer / customer or others in the use of the device.