Model CBM-3 Counterbore Module

92-0227 : Rev. 070529

MAINTENANCE

All components should be cleaned and coated with a light film of oil prior to storage.

When the Counterbore Module is operated in such a way that the Module collects
chips or debris near the Tool Holder, the Counterbore Module should be cleaned
after each cutting operation.

DAILY

Wipe the unit down and spray with rust preventative under severe humidity condi-
tions.

Visually inspect for loose Screws, missing Bolts, or damage due to impact.

Contact TRI TOOL INC. if major repair is required.

Tighten or replace Screws or other parts as required.

MONTHLY

Thoroughly clean and lubricate the Feed Tube and Boring Bar.

Feed the Boring Bar out of the Feed Tube.

With a clean, dry rag, thoroughly wipe down the Boring Bar and the Feed
Tube.

Be sure that all of the old lubrication, chips, and dirt are completely removed.

Lubricate the Feed Tube, Feed Nut, and Boring Bar with a light machine oil.

Reassemble the Boring Bar into the Feed Tube.