Westermo DDW-226 User Manual

Page 14

Advertising
background image

14

6642-22402

Ethernet TX
Electrical specification

IEEE std 802.3. 2005 Edition

Data rate

10 Mbit/s or 100 Mbit/s, manual or auto

Duplex

Full or half, manual or auto

Circuit type

TNV-1

Transmission range

Up to 150 m with CAT5e cable or better

Isolation to

All other

Connection

RJ-45 auto MDI/MDI-X

Shielded cable

Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails.*

Conductive housing

Yes

Number of ports

4

* To minimise the risk of interference, a shielded cable is recommended when the cable is located

inside 3 m boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and
connected to this port.

SHDSL
Electrical specification

ITU-T G.991.2 Annex B

Data rate

192 kbit/s to 15.3 Mbit/s

Protocol

EFM according to IEEE 802.3-2005

Transmission range

According to ITU-T G.991.2 depending on line quality

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required

Number of ports

2

RS-232
Electrical specification

EIA RS-232

Data rate

300 bit/s – 115.2 kbit/s

Data format

7 or 8 data bits, odd/even/none parity, 1 or 2 stop bits

Protocol

Transparent, optimised by packing algorithm

Circuit type

SELV

Transmission range

15 m / 49 ft

Isolation to

Power, DSL, Ethernet

Galvanic connection to

USB, Console

Connection

RJ-45

Shielded cable

Not required

Conductive housing

Yes

Advertising