Factory default on ddw-226, Referring documents – Westermo DDW-226 User Manual

Page 20

Advertising
background image

20

6642-22402

Factory default on DDW-226

It is possible to set the unit to factory default settings by using two standard Ethernet
RJ-45 cables.
1. Power off the switch and disconnect all Ethernet cables and DSL cables.
2. Connect one Ethernet cable between Ethernet port 1 and Ethernet port 4, and

another Ethernet cable between Ethernet port 2 and Ethernet port 3.
The ports need to be connected directly by Ethernet cables, i.e., not via a hub or
switch. Use straight cables – not cross-over cables – when connecting the port pairs.

3. Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red.

The ON LED flashing indicates that the unit is now ready to be reset to factory
default. You now have the choice to go ahead with the factory reset, or to skip
factory reset and boot as normal.

• Go ahead with factory reset:

Acknowledge that you wish to conduct the factory reset by unplugging one of the
Ethernet cables. The ON LED will stop flashing.
This initiates the factory reset process*, and after approximately 1 minute the unit
will restart with factory default settings. When the switch has booted up, the ON
LED will typically show a green light (a red light is shown if only one of the DC
power feeds is connected).

• Skip the factory reset:

To skip the factory reset process, just wait for approximately 30 seconds
(after the ON LED starts flashing RED) without unplugging any of the Ethernet
cables. The switch will conduct a normal boot with the existing settings.

* Note Do not power off the unit while the factory reset process is in progress.

Referring documents

Type

Description

Document number

Management Guide

Westermo OS management guide

6101-3201

Advertising