Switch block 1 – s1 switch block 2 – s2, Selection of baud rate, Termination of the line – Westermo TD-29 User Manual

Page 10: Carrier active using rts or incoming data, Selection of transmission level, Selection of minimum detection level

Advertising
background image

10

6611-2002

Termination of RS-422*

Factory setting

Termination of RS-485*

Character format

S1

10 bit/s

ON

1 2 3 4 5 6 7 8

S1

11 bit/s

ON

1 2 3 4 5 6 7 8

Selection of Baud rate

S1

2 400 bit/s

ON

1 2 3 4 5 6 7 8

S1

4 800 bit/s

ON

1 2 3 4 5 6 7 8

S1

9 600 bit/s

ON

1 2 3 4 5 6 7 8

S1

19.2 kbit/s

ON

1 2 3 4 5 6 7 8

Termination of the line*

S1

No

termination

ON

1 2 3 4 5 6 7 8

S1

Termination

ON

1 2 3 4 5 6 7 8

Carrier active using

RTS or incoming data

S1

Data

ON

1 2 3 4 5 6 7 8

S1

RTS

ON

1 2 3 4 5 6 7 8

Selection of transmission level*

S1

–9 dBm

ON

1 2 3 4 5 6 7 8

S1

5 dBm

ON

1 2 3 4 5 6 7 8

Selection of

minimum detection level

S1

–30 dBm

ON

1 2 3 4 5 6 7 8

S1

–20 dBm

ON

1 2 3 4 5 6 7 8

S1: 8 not used

* Load 600 Ω

S2

No termination

ON

1 2 3 4

S2

Termination

ON

1 2 3 4

S2

No termination

ON

1 2 3 4

S2

Termination

ON

1 2 3 4

S1

ON

1 2 3 4 5 6 7 8

S2

ON

1 2 3 4

* The line should be terminated at the end points.

* The line should be terminated at the end points.

* The line should be terminated at the end points.

Switch block 1 – S1

Switch block 2 – S2