Description, Environmental conditions – Westermo TD-29 User Manual

Page 5

Advertising
background image

5

6611-2002

Description

The TD-29 is designed for communication on 2-wire copper cable (twisted pair).
Multidrop or point to point is possible.The TD-29 will support half duplex at baud rates
up to 19.2 kbit/s.
The TD-29 is easy to configure for different operating conditions with DIP-switches.
Character formats, baud rate, transmission level, DCD detection level and communication
interface are selectable. DTE-equipment can be connected through an RS-232 or
an RS-422/485 interface.The RS-232 connection can be made through either the DB-9
connector or screw terminal on the front of the unit.There are four baud rate settings.
When using the RS-232 interface the direction of communication can be controlled by
RTS handshake signal or incoming data.
When connecting in multidrop configuration the maximum bus length depends on the
number of units connected. (see below)

Maximum range and signal loss

Transmission speed

(bit/s)

Range

point-to-point

(km)

Signal loss

(dB/km)

Loss per unit

(multidrop) (dB)

2 400

16

1.5

0.2

4 800

14

1.7

0.2

9 600

11

2.1

0.3

19 200

9

2.5

0.4

Measured with Cat. 5 cable UTP 4x2x24AWG. Signal level >–24 dBm. The bus length depends on the line quality.

Turning time (RS-485)

Data rate bit/s

Turning time µs

2 400

800

4 800

400

9 600

320

19 200

300

Environmental conditions

Environmental phenomena

Basic standard

Description

Test levels

Temperatures

Operating

5 to +50°C (41 to +122°F)*

Storage and transport

–40 to +85°C (–40 to +185°F)

Humidity

Operating

5 to 95 % relative humidity

Storage and transport

5 to 95 % relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Advertising