Interface specifications – Westermo RFI-2xx User Manual

Page 13

Advertising
background image

13

6641-22310

Interface specifications

Power and CPU
Rated voltage

20 to 48 VDC

Operating voltage

16 to 60 VDC

Rated frequency

DC

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required

Power
Rated voltage

20 to 48 VDC

Operating voltage

16 to 60 VDC

Rated current

RFI-219-T3G

0.63 (0.79*) A @ 20 VDC
0.26 (0.33*) A @ 48 VDC

RFI-211-T3G

0.43 (0.60*) A @ 20 VDC
0.19 (0.25*) A @ 48 VDC

RFI-215-F4G-T3G

0.63 (0.82*) A @ 20 VDC
0.26 (0.33*) A @ 48 VDC

RFI-207-F4G-T3G

0.55 (0.72*) A @ 20 VDC
0.23 (0.29*) A @ 48 VDC

RFI-219-F4G-T7G

0.93 (1.12*) A @ 20 VDC
0.38 (0.45*) A @ 48 VDC

RFI-211-F4G-T7G

0.87 (1.06*) A @ 20 VDC
0.35 (0.43*) A @ 48 VDC

RFI-219-F4G-T7G-F8

1.30 (1.47*) A @ 20 VDC
0.52 (0.58*) A @ 48 VDC

Inrush current

40 mA2s @ 20 VDC
257 mA2s @ 60 VDC

Startup current**

2x Rated current

Rated frequency

DC

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

All other

Connection

Detachable

Connector size

0.2 - 2.5 mm2 (AWG 24 - 12)

Shielded cable

Not required

* With 500mA USB load
** External supply current capability for proper start-up

Advertising