Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact

± 6 kV

Enclosure air

± 8 kV

RF field AM modulated IEC 61000-4-3

Enclosure

20 V/m 80% AM (1 kHz), 80 – 2700 MHz

Fast transient

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 1 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power frequency
magnetic field

EN 61000-4-8

Enclosure

300 A/m 0, 16.7, 50, 60 Hz

Pulse magnetic field

EN 61000-4-9

Enclosure

300 A/m

Radiated emission

CISPR 16-2-3

Enclosure

Class B

ANSI C63.4
(FCC part 15)

Enclosure

Class B, 30 – 6500 MHz

Conducted emission

CISPR 16-2-1

DC power ports
Telecommunication
ports

Class B

Dielectric strength

EN 60950

Signal port to other
isolated ports

1.5 kVrms 50 Hz 1 min

Power port to other
isolated ports

1.5 kVrms 50 Hz 1 min

Temperature

EN 60068-2-1
EN 60068-2-2

Operating

–40 to +70ºC (all models)

Storage & Transport

–40 to +85ºC (all models)

Maximum surface
temperature

135 °C (temperature class T4)

Humidity

EN 60068-2-27

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 years

Vibration

IEC 60068-2-6

Operating

7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
(Wall-mounted or DIN-rail mounted using TH
35-15 according to EN 60175)

Shock

IEC 60068-2-27

Operating

15 g, 11 ms
(Wall-mounter or DIN-rail mounted using TH
35-15 according to EN 60175)

Enclosure

UL 94

Aluminium / Zink

Flammability class V-0 (all models)