29

6614-2202

The TR-36 is connected to Power meter which is remotely monitored and the TR-36
shares the PSTN line with normal telephones which is preferred not to give a Ring signal
when the meter is read.

The TR-36 is setup to answer calls on the Caller ID received, the valid numbers to
answer is programmed into the TR-36. There exists a number of standards for sending
Caller ID please check which standard is used by your operator, the TR-36 supports the
major implementations. In this example the DTMF Caller ID version is used. Note some
implementations doesn’t give the possibility to make a silent answer since the Caller ID
is sent between first and second ring signal.

On the originating side any type of modem able to call a PSTN number can be used.

Configure the TR-36

AT&F

Set the unit to factory default

AT+IPR=9600

DTE baudrate 9600

AT+ICF=3,4

Character framing 8 data, 1 stop, parity none

ATS0=0

No auto answer on Ring signals

ATQ1E0&C1&K0&A1

Suitable for PLC communication

AT&W

Save settings

AT*WACCTAB=1,”016428000”
AT*WACCTAB=2,”016480250”

Set the valid A-numbers for automatic answering

AT*WCID=3,3

Set Caller ID to A-number answer with DTMF coded numbers

… Silent answering on predefined numbers TR-36

PSTN

Network