Westermo TR-36 User Manual

Page 31

Advertising
background image

31

6614-2202

… Leased line connection using 2- or 4-wire

Leased line connections can be set up using either 2- or 4-wire.When renting a 4-wire
line from a telephone company one pair of cables for transmission and one pair for
reception are usually provided.

The maximum transmission distance depends on the attenuation of the line. The maxi-
mum value is theoretically 30 dBm. To have a good error rate it is recommended to keep
the attenuation under 25 dB. When renting lines from a telephone company a longer
transmission distance is normally possible as the signals are probably transmitted over
PCM-lines, i.e. fibre optic or other media with low attenuation.

To set the modem for leased line applications use the dip switches.

Configure the units

S2:1, 2 ON
S2:2 ON

Leased line calling
Leased line answering

S2:5 OFF

Leased line 2-wire

S2:5 ON

Leased line 4-wire

S1

Sets speed and parity for the RS-232 port.

S3

Decides line-speed. Must be set in direct mode applications.

To make switch setting active the power must be cycled OFF -> ON.

Leased Line

Resistance, attunation and distance for different wires

Tele Cable

Area

Resistance for
double cable

Attunation

Recommended
Max distance
(25 dB)

Max Distance
(30 dB)

Ø 0,5 mm*

≈ 0,2 mm2

175 Ω/km

1,1 dB/km

23 km

27 km

Ø 0,6 mm*

≈ 0,3 mm2

123 Ω/km

0,9 dB/km

28 km

33 km

Ø 0,7 mm*

≈ 0,4 mm2

93 Ω/km

0,8 dB/km

31 km

38 km

Ø 0,8 mm

≈ 0,5 mm2

73 Ω/km

0,7 dB/km

36 km

43 km

Ø 0,9 mm

≈ 0,64 mm2 59 Ω/km

0,6 dB/km

42 km

50 km

* Frequently used in the local network

Advertising