Self Cleaning Continuous Filter Chapter 3: Installation

25

Safety Latches
Due to the extreme pressure that your unit operates under, it has been equipped with safety
latches on the door. These latches require specific amounts of pressure and turns (shown in
the tables below) to undo them.

Release Pressure (Lbs.)

Pressure Per Turn

Change (Lbs.)

Per ½ Turn

Full Turns

Available

Minimum

Maximum

43

180

5.96

2.98

23

• For negative systems, each latch must be set at “0” turns for minimum release pressure

(43 lbs.). With three (3) latches per door, the total force required to open the door is
129 lbs. (40 lbs./sq. ft.)

• For positive systems, each latch must be set to open just above operating pressure (See

table below).

Pressure at SCF

Inlet (in. Wg.)

Column 1

Column 2

Over

Up To

Turns From Loosest Position

Turns Off of Tightest Position

5

0

23

5

6

1

22

6

7

2

21

7

8

3

20

8

9

4

19

9

10

5

18

10

11

6

17

11

12

6-1/2

16-1/2

12

13

7-1/2

15-1/2

13

14

8-1/2

14-1/2

14

15

9-1/2

13-1/2

15

16

10-1/2

12-1/2

16

17

11-1/2

11-1/2

To adjust the latch, place it in the door closed position. When in this position, one rivet
which holds the laminated cam together is exposed.

Adjusting Unmounted Latches

1. Turn the adjusting screw (Shown in Figure 9 below) counter-clockwise to its lowest

position, making sure that the square nut does not come off the ball pin.

Figure 14: Safety Latch Components

2. Tighten the adjusting screw until the desired pressure setting is reached (See Column

1 in the Table above for pressure setting).