3.0 Pre-Operational Procedures

3.1 Scope

This section contains the information required to carry out pre-operational procedures, and a
checklist of items which should always be reviewed prior to a production run.

ΗΗΗΗΗΗΗ

DANGER

ΗΗΗΗΗΗΗ

Before undertaking any machine repairs or maintenance, always

make certain that the machine disconnect switch is turned to the

OFF position or that the control enclosure is disconnected from

the main power source. When extensive work is anticipated, either

place a sign indicating that the main disconnect switch is to remain

off onto the switch or lock the switch to prevent accidental

activation by someone unaware of work in progress.

3.2 Electrical Test

Before applying power to the machine, check the incoming voltage from L1 to L2, L2 to L3,
and L1 to L3 (see wiring diagram packed with the machine). The voltage should be the same
as indicated on the silver tag in the control enclosure. If the voltage is not the same, contact
the Colortronic Service Department for voltage modification.

Once it has been determined the voltages are proper, it is necessary to start the motors and
check for the proper direction of rotation.

Turn the main disconnect switch to the ON position.

Press the Granulator START pushbutton to power the granulator motor. Visually compare
the direction of the motor shaft rotation to the rotation arrow label (counter-clockwise when
viewed from the shaft end). If the motor turns in the opposite direction, reverse any two
incoming power leads.

Once the rotation direction is correct, the remaining electrical controls need to be tested as
follows:

Press the Granulator STOP pushbutton and allow the machine to stop.

For granulators equipped with conveyors, fans, or etc., test their operation also by

pressing the appropriate pushbutton. Check fan outlets for proper airflow.

For granulators with Emergency Stop pushbuttons, test the buttons to insure all motion

stops.

Open the front doors to verify the safety interlock switch shuts the machine off.