Start-up – AIRLESSCO G-Force II 2525 DD User Manual

Page 13

Advertising
background image

Operation

333031E

13

Start-Up

1. Engage trigger lock and point gun away from your-

self or anyone else. Make sure water supply is fully
turned on.

2. Disengage trigger lock and squeeze trigger. Low

pressure water will begin flowing from nozzle.

3. Make sure gun remains in an open position while

starting engine. NOTE: Brace yourself. Gun will
kickback from high pressure created by pump once
engine has started.

4. Steady unit during engine start-up. See accompany-

ing engine manual for correct procedures needed to
start engine.

5. Once engine has started, perform the following pro-

cedures with gun open:

6. Trigger gun several times. Make sure to engage

trigger lock whenever changing quick-connect noz-
zles.

This pressure washer delivers a high pressure spray
and a variety of spray patterns. There are many clean-
ing jobs that can be done without the use of detergents.
If a cleaning agent is required, see Cleaning with
Detergents
(page 14) for correct procedures.

Never look directly into the nozzle. High pressure
water creates a risk for severe injury.

FIRE AND EXPLOSION HAZARD
Inspect for system oil leaks and fuel leaks. If a fuel
leak is found, immediately turn off unit. Make sure all
damaged parts are replaced and mechanical
problems are corrected prior to operation of unit. If
service is required, contact Graco Customer Service.

INJECTION HAZARD
Inspect high pressure hoses for kinking, cuts and
leaks. If a cut or leak is found, do not touch hose at
leak. Turn unit off immediately. Replace hose before
restarting unit. Make sure all damaged parts are
replaced and mechanical problems are corrected
prior to operation of unit. If service is required,
contact Graco Customer Service.

NOTICE

Do not allow unit to operate in bypass mode (with trig-
ger closed) for more than three minutes without trig-
gering gun. This can cause premature failure of pump
packing seals and result in costly pump repair.

NOTICE

Do not allow spray pattern to remain on a fixed area
for an extended period of time. Possible damage to
that area may occur.

Advertising