AIRLESSCO G-Force II 2525 DD User Manual

Page 18

Advertising
background image

Troubleshooting

18

333031E

Water in pump oil

Humid air condensing inside crank-
case

Change oil as specified in Mainte-
nance on page 15.

Worn packings

Install new packings.

Oil seals are leaking

Install new oil seals.

Packings failing frequently or prema-
turely

Scored, damaged, or worn plungers

Install new plungers.

Abrasive material in the fluid being
pumped

Install proper filtration on pump inlet
plumbing.

Inlet water temperature too high

Check water temperature. It should
not exceed 140°F (60°C).

Over pressurized pump

Do not modify any factory-set adjust-
ments. See Equipment Misuse Haz-
ard on page 6.

Excessive pressure due to partially
plugged or damaged nozzle

Clean or replace nozzle. See Nozzle
Connection
on page 10.

Pump running too long without spray-
ing

Never run pump more than 10 min-
utes without spraying.

Running pump dry

Do not run pump without water.

Strong surging at inlet, and low pres-
sure on discharge side

Foreign particles in the inlet or dis-
charge valve, or worn inlet and/or
discharge valves

Clean or replace valves.

Problem

Cause

Solution