Troubleshooting

333031E

17

Troubleshooting

1. Follow Pressure Relief Procedure, page 12,

before checking or repairing gun.

2. Check all possible problems and causes before dis-

assembling gun.

Problem

Cause

Solution

Engine not starting or hard to start

No gasoline in fuel tank or carburetor Fill the tank with gasoline and open

fuel shut off valve.
Check fuel line to carburetor.

Low oil

Add oil to proper level.

Start/Stop switch in STOP position

Move switch to START position.

Water in fuel, or old fuel

Drain fuel tank and carburetor. Use
new fuel, and make sure spark plug
is dry.

Engine flooded or improperly choked Open choke, and crank engine sev-

eral times to clear out gas. Make
sure spark plug is dry.

Dirty air cleaner filter

Remove and clean.

Dirty spark plug, wrong gap, or
wrong type

Clean spark plug, adjust the gap, or
replace.

Gun not triggered

Trigger gun while starting engine.

Engine not operating properly or
lacking power

Partially plugged air cleaner filter

Remove and clean.

Spark plug dirty, wrong gap, or
wrong type

Clean spark plug, adjust the gap, or
replace.

Pressure too low and/or pump run-
ning roughly

Worn or wrong size tip

Replace with tip of proper size

Inlet filter clogged

Clean filter. Check more frequently.

Worn packings, abrasives in water,
or natural wear

Check filter. Replace packings.

Inadequate water supply

Check water flow rate to pump.

Belts slipping

Tighten or replace belts; use correct
belts, and replace both at same time.

Fouled or dirty inlet or discharge
valves

Clean inlet and discharge valve
assemblies. Check filter.

Restricted inlet

Check if garden hose is collapsed or
kinked.

Worn inlet or discharge valves

Replace worn valves.

Leak in high-pressure hose

Replace high-pressure hose.

Water leaking from under pump man-
ifold

Worn packings

Install new packings.