Flush mount – Airmar G2183 GPS User Manual

Page 11

Advertising
background image

11

Flush Mount

1. Remove the label from over the sensor unit’s socket (see Figure 3)

.

Apply

removable thread locker to the two studs supplied. Screw the studs into the
underside of the sensor unit (part A).

2. Using the gasket (part B) as a template, position it at the selected mounting

location upside down with the arrow facing forward. Mark the position for the
two mounting holes and the center hole for the cable.

3. Using a 3mm or 1/8" bit, drill the pilot holes. Using a 6mm or 1/4" bit, drill the two

mounting holes for the studs. Drill the cable hole with a 38mm or 1-1/2" hole saw.
Fiberglass—Minimize surface cracking by running the drill in reverse until the
gelcoat is penetrated.

4. Pass the instrument connector-end of the cable through the center of the gasket

and through the center mounting hole in the vehicle/boat.

5. Plug the cable firmly into the sensor unit.
6. Orient the gasket with the arrow facing in the same direction as the alignment tab

on the sensor unit. Push the gasket onto the studs and slide it over the connector.
NOTE: The gasket fits one way only. A groove in the gasket fits over the
alignment tab on the connector.

7. With the sensor’s alignment tab pointing forward, push the studs through the

mounting surface. Check to be sure the gasket is tucked under the lip of the
unit.
From underneath the mounting surface, slide a flat washer and lock
washer onto each stud. Fasten them with the thumb nuts. Hand tighten only.
Do not over tighten.

Figure 3. Flush mount