AML M5900 Portable Batch Data Terminal User Manual

Page 37

Advertising
background image

30

ON

Uniform Symbology Specification (3-1-3 mod 10)

OFF* None (no check digit required)

OPCC Check Digit

Specifies if the OPCC check digit type will be used with Interleaved 2 of 5:

ON

Optical Product Code Council (2-1-2 mod 10)

OFF* None (no check digit required)

Send Check Digit

ON

Transmit the Interleaved 2 of 5 check digit with the bar code data.

OFF* The check digit is not transmitted.

Enable Fixed Length

ON

Read only Fixed Length Interleaved 2 of 5 bar code labels that match the
lengths defined in “Set Fixed Length #1 - #3” options below. The check
digit can be on or off.

OFF* Disable Fixed Length mode. Read all Interleaved 2 of 5 labels without

regard to length.

<--> 1

Sets the first valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to
enter the length. Valid lengths are 02 to 60 characters. By definition, the lengths
of Interleaved 2 of 5 labels are an even number of characters. The default Fixed
Length is 2 characters.

<--> 2

Sets a second valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to
enter the length. The default length is set to 6 characters.

<--> 3

Sets a third valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to
enter the length. The default length is set to 6 characters.