Specifications, Introduction – Empire Products SR-18T-3 User Manual

Page 5

Advertising
background image

16009-1-0504

Page 5

Model

SR-10T

SR-18T

SR-30T

Input BTU/HR (KW/H) Five Plaques

30,000 (8.8)

BTU/HR (KW/H) Three Plaques

18,000 (5.3)

BTU/HR (KW/H) One Plaque

10,000 (2.9)

Height

22" (559mm)

22" (559mm)

22" (559mm)

Width

11 7/8" (302mm)

18" (457mm)

24 1/8" (613mm)

Depth

6 1/2" (165mm)

6 1/2" (165mm)

6 1/2" (165mm)

Gas Inlet

3/8" (10mm)

3/8" (10mm)

3/8" (10mm)

Accessories
Blower

SRB-18T

SRB-30T

Floor Stand

SRS-10*

SRS-18

SRS-30

*Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation.

The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFPA54 defines an unconfined space as “a space whose volume
is not less than 50 cubic feet per 1,000 Btu per hour (4.8m

3

per kw) of the aggregate input rating of all appliances installed in that space.”

SPECIFICATIONS

Instructions to Installer
1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card

supplied with unvented room heater.

3. Installer should show owner how to start and operate unvented

room heater.

Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation of
an unvented room heater.

This appliance may be installed in an aftermarket* permanently
located, manufactured (mobile) home, where not prohibited by
state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from

the manufacturer.

This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other
gases.

General Information
This appliance is design certified in accordance with American
National Standards Institute Z21.11.2b by the Canadian Standards
Association Laboratories as an Unvented Room Heater and shall
be installed according to these instructions.

Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not shown
on the rating plate is the responsibility of the person and
company making the change.

Important
All correspondence should refer to complete Model Number,
Serial Number and type of gas.

Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the
Btu output of the unit. Contact the gas company for the heating
value. Contact the manufacturer or your gas company before
changing spud/orifice size.

Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation, or company that either in
person or through a representative is engaged in and is responsible
for (a) the installation, testing, or replacement of gas piping or (b)
the connection, installation, testing, repair, or servicing of
equipment; that is experienced in such work; that is familiar with
all precautions required, and that has complied with all the
requirements of the authority having jurisdiction.

The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1
(latest edition).*
*Available from the American National Standards Institute, Inc.,
11 West 42nd St., New York, N.Y. 10036.

High Altitudes
For altitudes/elevations above 2,000 feet (610m) ratings should
be reduced at the rate of 4 percent for each 1,000 feet (305m)
above sea level. Contact the manufacturer or your gas company
before changing spud/orifice size.