SR-18T CLEARANCES

When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.

Left side 6 inches (152mm). Right side 6 inches (152mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.

Figure 5 (SR-18T)

SR-30T CLEARANCES

When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.

Left side 8 inches (203mm). Right side 8 inches (203mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.

Figure 6 (SR-30T)

36" (914mm) MIN

6" (152mm)

MIN

6" (152mm)

MIN

2" (51mm)

MIN

36" (914mm) MIN

8"

(203mm)

MIN

8"

(203mm)

MIN

2"

(51mm)

MIN