Sr-10t clearances – Empire Products SR-18T-3 User Manual

Page 8

Advertising
background image

Page 8

16009-1-0504

SR-10T CLEARANCES

When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.

Left side 6 inches (152mm). Right side 6 inches (152mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 24 inches (610mm).
Minimum vertical clearance from a projection above the
appliance (shelves, window sills, etc.) 14 inches (356mm).
Maximum horizontal extension of projection above the
appliance 12 inches (305mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.

Figure 3 (SR-10T)

Figure 4 (SR-10T)

24 " MIN

(610mm)

2 " MIN

(51mm)

6 " MIN

(152mm)

6 "MIN

(152mm)

14" MIN

(356mm)

14" MIN

(356mm)

24 " MIN

(610mm)

2 " MIN

(51mm)

12" MAX

(305mm)

0" (0mm) CLEARANCE
TO REAR WALL

Advertising
This manual is related to the following products: