Setup, Bd a – ARAG DIGIWOLF - Battery powered version User Manual

Page 8

Advertising
background image

8

3

CONTROlS IN THE mENU

0.0 l

2

1

0.0 l/min

SwITCH ON

The display turns on automatically at liquid passage. If you need to switch on the
device to check or modify data, press

OK

.

DigiWolf switches on and displays the figure shown.

Press the key to see the succession of different values written in full (central part
of the display).
At first device switch on, or after battery replacement, the device will briefly
display its name and software version.

0.0 l

2

1

0.0 l/min

ACCESS TO SETUP mENU

Press the keys for

2 seconds at the same time to access setup menu.

Setup menu

Calibration

Flowrate alarms

Display

A

B

SElECTION AND ACCESS TO mENU ITEmS

A

Press in succession to move through items (the selected item is highlighted with

a black band)

B

Press to access the selected item

Three dots under an item show the presence of another setup menu.

Flowrate constant

Min value

Max value

C

1

50000

0123

0

B

D

A

mODIFYING DATA

A

Press to toggle from one digit to another

B

Press in succession to modify the value of the digit highlighted by the cursor

C

Press to confirm the change. The display goes back to the previous screen.

D

Press to exit current page without confirming changes.

Fig. 12

Fig. 13

Fig. 14

Fig. 15

SETUP

Advertising