INSTALLATION INSTRUCTIONS

INSTALLING THE EURO 25 GAS FIREPLACE INSERT HEATING APPLIANCE

INTO VENTED ZERO-CLEARANCE GAS FIREPLACE:

CANADIAN HEATING PRODUCT MODEL MONTIGO 28 SERIES

1. Remove the louvers and screens or glass door.
2. Remove the burner/sandpan assembly, valve and pilot assembly from the firebox bottom

plate. Leave the plate in place to support the gas insert.

3. Remove the bottom front trim.
4. Push the deflector at the back of the firebox against the back of the firebox until it is fairly

flat against the back.

5. Bend the two front deflector plates forward and up. Measure the height of the front opening.

The opening must be 15 ¼” or higher.

6. The preparation of the host gas fireplace is complete. See Appendix A of the Euro-25

manual for further instructions. All installation requirements in the manual must also be
carefully observed and followed.

7. Use Archgard 25-ICKIT5 connector kit to connect the insert to the host’s B-vent or connect

a 4” diameter flexible aluminum gas vent from the insert to the host’s vent cap.

CAUTION: Installation must be conducted by a qualified gas appliance installer. Gas and

electrical power must be disconnected from the host gas fireplace before
installation can begin.

ITEM 3.

REMOVE

TO

BEND

ITEM 4.

TO

ITEM 5.

BEND

* Optional custom surround is available for the Montigo 28 Series, Part # 25-BP. With this part,

minimal finishing work is required. It will fill in the opening around the insert. The top louver
of the Montigo is maintained. Please contact Archgard Industries for the availability of this
part.

15 ¼”