Vii. technical specifications, Viii. points for attention – ARM Electronics SDKBD2&3 User Manual

Page 11

Advertising
background image

Figure 8

VII. Technical Specifications:

‹

Communication between Speed Dome Camera and Controller:Port to multi-port and half duplex

function.

‹

Communication connector: RS-485.

‹

Baud Rate of Communication:Four baud rates i.e. 2400bps, 4800bps, 9600bps and 19200bps.

‹

Distance of Communication:1200m in maximum

‹

Power Supply:DC12V/1A

‹

Size:315 × 165 × 57(mm)

‹

Weight:2 Kg

‹

Number of controlled speed dome camera up to 32.

VIII. Points for Attention:

‹

Please read the operation manual of the keyboard carefully before using it.

‹

The operation manual is mainly focused on all functions of PELCO-D, PELCO-P and COP-2

Protocols. For other different protocols, operations could be something different and those different

parts will be listed on “Supplementary Description of the Keyboard Controller” in details.

‹

The keyboard takes DC12V power supply. Please confirm the voltage and polarity before the power

supply is switched on.

‹

Do not place the keyboard under the rain or on wet place so as to avoid short circuit or electrical shock.

‹

As the keyboard is a sophisticated electronic device, you should never open the case so as to avoid the

occurrence

of

trouble.

‹

The keyboard has integrated multiple protocols, and you are pleased to select correct protocol and the

baud rate. When switching on power supply, take care of the selected protocol and the baud rate on the

first

screen.

‹

In case the keyboard controls the multiplexer, the operation of combination buttons is as follows:

Press one button first, and press the other button after release the first one.

For example:When enter/exit setting of the menu (Function + Zoom), press Function button first, and

press Zoom button after Function button is released. While use Func alone, please put it down until

“Motion Detect OK” appears.

‹

When control the multiplexer through adapter box, select the multiplexer address:

N + CAM/ID (N: multiplexer address 1--128).

Advertising