ARM Electronics SDKBD2&3 User Manual

Page 8

Advertising
background image

track is 4 seconds

z Speed Range:1 to 8 from the fastest to the lowest. Any speed outside the range will be referred as

the 1st class; the range of the dwelling time is:1 to 255.

z When the No. N preset point is set as No. 0, then all preset points before the No. N preset point in

the track will be valid however all numbers of preset points afterward and their speed and dwelling

time shall be set as 0 automatically.

z After tracks are edited, press OFF to store and exit while push the joystick to exit without storage.

6. Run Cruise Track: [SHOT]+[N]+ [Enter]

Display:Input Tour No:01

Description:N –– No. of the track from 1 to 6.

Function:Tour the No. N track and stop tour by pushing the joystick.

7.

Stop Cruise Track: [SHOT]+[N]+ [OFF]

Display:Input Tour No:01

Description:N –– No. of the track from 1 to 6.

Function:Stop the No. N track or stop tour by pushing the joystick.

8. Cancel Cruise Track: [SHOT]+[N]+ [OFF] (Pressing [OFF] down until “ Clear Tour OK ”appears)

Display:Input Tour No:01

Description:N –– No. of the track from 1 to 6.

Function:Delete the No. N track

9. Auto Pan ON (Operation of COP-2 Protocol): [AUTO]+[P1]+[ON]+[P2]+[OFF]

Display:Input 1st No:001

Description:P1–––– the starting scan No. of preset point from 1 to 128, which should be set already.

Display:Input 2nd No:002

Description:P2–––– the ending scan No. of preset point from 1 to 128, which should be set already.

If P1 = P2 or P1 and P2 are coincided, the speed dome will make scan in range of 360°.

Note:

(1) For PELCO-D and PELCO-P Protocols the way of operation is as follows:

‹

Set the Starting Scan Position: Transfer the speed dome to the starting scan position, operation

[AUTO]+[ON]

‹

Set the Ending Scan Position: Transfer the speed dome to the ending scan position, operation

[AUTO]+[OFF]

‹

Run Auto Pan:[AUTO]+[ENTER]

(2) Auto Pan operation takes the following parameters. You must set these parameters before using a

Auto Pan command to begin the scan operation. You can use the scan Stop command or PT scan stop

command to stop the scan. Setting scan condition:

z Auto Pan Position(First specify position, second specify position)
z Auto Pan Speed and Direction.

10. Stop Auto Pan:[AUTO]+[OFF] (only for

COP-2

protocol)or push the joystick to stop scan.

11. Control the Zoom of the Camera:[WIDE]/[TELE]

12. Control the Focus of the Camera:[FAR]/[NEAR]

13. Control the Iris of the Camera:[OPEN]/[CLOSE]

14. Auxiliary Control of the Camera: By combination of [F1] and [ON], [OFF] buttons, you can set some

data of the camera, and functions are listed as follows:

Definition of Keyboard Operation

No. of

Value N

Control Object

[F1]+N+[ON] [F1]+N+[OFF]

0

Camera Power Supply/Reset Control

Power ON/OFF

Switching

Camera Reset

Advertising