Dome camera control – ARM Electronics XR&HD480 Series User Manual

Page 6

Advertising
background image

6

Dome Camera Control

Dome Camera Connection & Settings:

• See section Pin Definition of Alarm I/O & RS-485 for RS-485 port pin definition.

Refer to the following figure. Connect the R+, R− terminals on the dome camera to the D+, D−
terminals on the RS-485 port by RS-485 cable respectively.

• To set up dome camera’s protocol and ID, press MENU to access the OSD main menu, and

select <Camera Setup>. Then select <Dome Protocol> and choose the corresponding
protocol. Next select <Dome ID> and choose a preferred ID number. Note that the ID number
must match the ID address defined by the dome camera.

• To configure the RS-485 parameters, select <System Setup> from OSD main menu, and then

select <RS485 Setup>. The default RS-485 settings are 9600 Baud, 8 Data Bits, 1 Stop Bit and
No Parity.

Control Buttons in Dome Camera Control Mode:

1

Set / Go Preset

5

Zoom In

9

Iris Open

13

Enter Dome Camera
Control Mode

2

Toggle Hint Screen

6

Focus Far

10

Enter / Auto

3

Go Presets 1~6

7

Focus Near

11

Pan / Tilt

4

Zoom Out

8

Iris Close

12

ESC

Advertising
This manual is related to the following products: