background image

Table F-2. Printing enabled/disabled signals and control conditions

On Line

(Indicator on)

SLCT IN

DC1/DC3

(Data on/off contr.)

ERROR

BUSY

ACKNLG

ON LINE

LOW

DC1 /DC3

(S

W

. 2-1/interface)

(no effect)

HIGH

HIGH/LOW

PULSED EA. CHAR.

ON LINE

HIGH

DC1 RECV’D

HIGH

HIGH/LOW

PULSED EA. CHAR

ON LINE

HIGH

DC3 RECV’D

HIGH

HIGH/LOW

PULSED EA. CHAR.

OFF LINE

HIGH/LOW

DC1/DC3

(no effect)

(no effect)

LOW

HIGH

NOT GENERATED

Printing

(Disabled/enabled)

ENABLED

(normal cond.)

ENABLED

*DISABLED

DISABLED

*Even though printing is disabled, data characters are received and acknowledged, since the printer is looking for another DC1 character,

which would allow it to resume printing.