Rule 103: corner pads allowed – Cascade Microtech InfinityQuad Probe Pad Layout Rules User Manual

Page 3

Advertising
background image

PN 154-631-2

www.cascademicrotech.com

InfinityQuad Probe PAD Layout Rules • 3

Table 3.

Available pitch and the recommended maximum operational frequency.

Rule 103: Corner Pads Allowed

Corner pads are allowed for all available pitches before and after touch down. However, reduced overtravel may be
required, as well as a

slight adjustment of the probe in the scrub direction to avoid collision with the quadrant probes.

75 µ

pitch

80 µ

pitch

100 µ

pitch

125 µ

pitch

150 µ

pitch

200 µ

pitch

250 µ

pitch

GSG

layout

110GHz

GS or SG

layout

67 GHz

N

OTE

InfinityQuad probes are fully quadrant compatible when used exclusively with the same
pitch. For quadrant compatibility with other types of pitches or probes, please contact Cas-
cade Microtech.

Quadrant capability: scope view