Timing menu – Ensemble Designs BrightEye 5 Analog Composite TBC and Frame Sync User Manual

Page 14

Advertising
background image

www.ensembledesigns.com

BrightEye 5 - Page 14

5

Analog Composite TBC and Frame Sync User Guide

BrightEye 5 Timing Menu

Timing Menu

The Timing menu is used to time the input signal to an external reference.

• Ver Time – Adjust the vertical timing of the signal in lines with reference to the Frame Sync

input. Default is 0 lines.

• Hor Time – Adjust the horizontal timing of the signal in clocks with reference to the Frame

Sync input. Range is -1700 - 1700 clocks, default is 0 clocks.

• Fine Phase – Adjust the fine phase of the signal in subpixels with reference to the Frame Sync

input. Range is -100 - 100 subpixels, default is 0 subpixels.

• Frame Sync – Set the Frame Sync function On to genlock to the external reference input to

the module or Off for no Frame Sync.

Advertising