Management ethernet port leds, Fan tray status leds – H3C Technologies H3C S10500 Series Switches User Manual

Page 95

Advertising
background image

85

The LEDs on the LSUM1MPU06B0 and LSUM1MPU10C0 MPUs are similar.

Figure 69

uses the

LSUM1MPU06B0 MPU as an example.

Figure 69 LEDs on the LSUM1MPU06B0 MPU

(1) Management Ethernet port LEDs

(2) Fan tray status LEDs

(3) Power module status LEDs

(4) LPU status LEDs

(5) MPU active/standby status LED

Management Ethernet port LEDs

The LSU1SUPB0 MPU uses the LINK and ACT LEDs to indicate the link status and data forwarding status

of the management Ethernet port.

Table 38 Management Ethernet port LED description for the LSU1SUPB0 MPU

LINK LED status

ACT LED status

Description

On Flashing

A link is present, and the management Ethernet port is receiving
or sending data.

On

Off

A link is present.

Off

Off

No link is present.

The LSUM1MPU06B0 and LSUM1MPU10C0 MPUs use the LINK/ACT LED to indicate the link status and

data forwarding status of the management Ethernet port.

Table 39 Management Ethernet port LED description for the LSUM1MPU06B0 and LSUM1MPU10C0

MPUs

LINK/ACT LED Status

Description

Flashing green

A link is present, and the management Ethernet port is receiving or
sending data.

Steady green

A link is present.

Off

No link is present.

Fan tray status LEDs

The LSU1SUPB0 MPU provides a set of LEDs (OK and FAIL) for each of the two fan trays (FAN0 and

FAN1).
The LSUM1MPU06B0 and LSUM1MPU10C0 MPUs each provide one set of LEDs (OK and FAIL) to

indicate the status of the fan tray (FAN).