Additional equipment (optional), Cleaning, Troubleshooting – Electrolux Thermetic 583394 User Manual

Page 11

Advertising
background image

OPERATING INSTRUCTIONS

62.9693.01

Page 9

5.

ADDITIONAL EQUIPMENT (optional)

6.

CLEANING

The appliance should be allowed to cool prior to cleaning.

Compartment
With normal use it is sufficient to clean the compartment with

hot water with an added grease solvent. Next, rinse with clean

hot water and dry with a cloth or absorbent paper. There is a

risk of corrosion if water with a high-salt content and/or food

are allowed to dry out in the pan.

Appliance casing
The appliance surfaces are of corrosion-free chrome nickel

steel. They are to be washed down with hot soapy water con-

taining a standard grease solvent cleaning agent and dried off.

General
Cleaning with steel brushes, wire or copper wool, products

containing sand etc. is to be avoided as such media will

destroy the surface and provide the opportunity for it to be

attacked and start to corrode. Spraying the appliance or its

parts with a water jet or high pressure cleaning equipment is

harmful and can cause malfunctions. Such practice is there-

fore forbidden. The drain in the cover plate, the bottom grid or

internal drain can be cleaned with a bottle brush.

Additional equipment, stirrer, strainer etc.
These loose parts are to be cleaned outside the boiling pan.

Where dimensions allow, these can be washed in a suitable

dishwasher.
Desinfection of scrapers:
The srcapers are locked to the stirrer with a bolt, which is

located inside the food zone. These parts must be disinfected

at regular intervals at temperatures above 179.6°F (82°C).

Best is to accomplish the disinfection after every food prepara-

tion below 179.6°F (82°C).

7.

TROUBLESHOOTING

Faults in the appliance are registered by the control electronics

and shown on the display (AT) dependent on the type of fault

by the letters A or E in combination with a double-digit number.

When the fault occurs, an intermittent acoustic signal sounds,

the power supply is interrupted and the lamp is switched off.

Press button (Q) again to acknowledge the error message

(acoustic signal).
Shut down the appliance if a continuous fault that prevents

operation arises (see section 5.5 Shutting down). Summon the

aftersales service to remedy the fault. Until this is done, the

appliance must not be used and must be disconnected from

the mains supply.

Strainer
The strainer appropriate for the

size of pan is firmly inserted into

the two retaining clips fitted to

the sides of the pouring lip.

Measuring rod
The measuring rod with filling

level marking is hung on the top

rim of the pan. The scale has 5

or 10 litre graduation marks.The

measuring rod must not be used

at the same time as the stirrer as

this may result in injury.

Discharge strainer
To prevent blocking the dis-

charge tap when pouring liquids

from the boiling pan, a discharge

strainer (1) can be placed in the

discharge pipe of the boiling pan.

The strainer is fitted and

removed with the aid of a hooked

rod (2).

Strainer for dough dumplings

and scraper
This accessory is for producing

Knoepfli or dough dumplings.

The stainer (1) is hung in the

compartment. The dough (2) is

placed in the strainer. Over the

hot water in the compartment,

the dough is pressed through the

holes in the strainer by moving

the scraper (3) back and forward

to form droplets.

Fig. 7

Accessories

E1

Failure of food tempera-

ture sensor

Summon service agent

and report reading

E2

Failure of jacket tempera-

ture sensor

Summon service agent

and report reading

E3

Failure of deaeration food

temperature sensor

Summon service agent

and report reading

E5

Failure of control circuit

board temperature sensor

Summon service agent

and report reading

E6

Sensor J15 of produce

temperature too high

Summon service agent

and report reading

E7

Sensor J16 of jacket tem-

perature too high

Summon service agent

and report reading

E8

Jacket pressure too high

Summon service agent

and report reading

E9

Failure of A/D converter

Summon service agent

and report reading

E10

Safety thermostat for dry

cycle protection has

responded

Summon service agent

and report reading

E11

Sensor of deaeration tem-

perature too high

Summon service agent

and report reading

E21

HACCP Master Personal

Computer is not con-

nected.

Discharge fault display

and signal by pressing but-

ton (Q).

E22

HACCP Interface

COP485.1 is not con-

nected.

Discharge fault display

and signal by pressing but-

ton (Q).

E23

HACCP configuration;

EEPROM COP485.1

(memory chip) has found a

reeding fault.

Discharge fault display

and signal by pressing but-

ton (Q) and repair fault.

E24

HACCP configuration;

EEPROM COP485.1

(memory chip) has found a

spelling fault.

Discharge fault display

and signal by pressing but-

ton (Q) and repair fault.

A2

Malfunction at burner igni-

tion

Acknowledge the warning

by pressing the button (Q).

Start again by pressing the

button (TT). Consider the

delay time of 30 to 60 sec-

onds.

A31

Advance warning: the

water in the jacket is due

for topping up

Acknowledge the warning

by pressing the button (Q).

The appliance can con-

tinue to be used. The

warning is given when-

ever the appliance is

reused. Summon service

agent occasionally and

report reading.

Advertising