After-sales service and repair, Technical data, Gas consumption – Electrolux Thermetic 583394 User Manual

Page 6: Packaging, Tests / certificates, Specification plate, Serial number ywwxxxxx, Further documents

Advertising
background image

GENERAL INFORMATION

62.9693.01

Page 4

1.5

AFTER-SALES SERVICE AND REPAIR

2.

TECHNICAL DATA

3.

GAS CONSUMPTION

4.

PACKAGING

All the packaging materials used are environmentally friendly.

They may burnt at an incineration plant or sent for recycling.

5.

TESTS / CERTIFICATES

All gas appliances are tested according to the standards

ANSI/NSF 4 - 2002 of Commercial Cooking, Rethermalization,

and Powered Hot Food Holding and Transport Equipment and

ANSI Z83.11-2002 and CSA 1.8-2002 of Gas Food Service

Equipment.
The appliance noise level is negligible. The statutory guidelines

are fulfilled; the sound pressure level is less than 70 dB (A).

6.

SPECIFICATION PLATE

The specification plate (E) is located in each case inside and

outside on the right of the control panel (C).

7.

SERIAL NUMBER YWWXXXXX

The serial number of the appliance is marked on the type

plate. The 8 digits give following information:
Y

last digit of the year of production

WW

week of production

XXXXX

running number

8.

FURTHER DOCUMENTS

Installation instruction

Service manual

Wiring diagram

Spare parts list

S

Boiling pans of this design and operating

mode do not require special acceptance

tests. They are subjected to a pressure and

operating test which meets the regulations on

the manufacturer's premises. Recurrent

pressure testing is not compulsory. To ensure

the complete operating efficiency and safety

of appliances, however, owners should

arrange for personnel authorised by the man-

ufacturer to check on all safety equipment

and to conduct pressure tests at regular

intervals.

S

In the event of a permanent fault which inter-

feres with operation, the appliance must be

switched off and disconnected from the

power supply.

S

Repair, maintenance work and other adjust-

ments are only to be carried out by an author-

ized specialist. The valid local and national

regulations must be observed. This applies

especially to burners, ignition, safety and con-

trol elements. Parts requiring replacement are

only to be replaced by original spare parts.

Periodic tests for gas leaks must be car-

ried out. A service contract is recom-

mended.

S

Cleaning and maintenance must be done only

when the heating surfaces are cold. Do not

use inflammable liquids to clean the appli-

ance.

S

An obligatory service check is required

annually.

PNC

Appliances

Appliance type

Width

Depth

Height

Power

Net

weight

Kettle size

inch

mm

kW

kg

gal

lt.

9CHG583394 GU5COEOOOO

47.2
35.4
35.4

1200

900
900

18

195

21.1

80

9CHG583395 GU5EOEOOOO

21

270

26.4

100

9CHG583396

KU5HOEOOOO

51.2
39.4
35.4

1300
1000

900

27

310

39.4

150

9CHG83397

KU5KOEOOOO

59.1
39.4
35.4

1500
1000

900

43

430

79.3

300

Power

G20 (m

3

/h)

G25 (m

3

/h)

G30/31 (kg/h)

18

1.73

2.04

1.42

21

2.02

2.38

1.65

27

2.6

3.06

2.13

43

4.14

4.88

3.39

Advertising