11

Step Command

Remarks

2.

Enter OpenFlow instance
view.

openflow instance instance-id N/A

3.

Activate or reactivate the

OpenFlow instance.

active instance

By default, an OpenFlow instance
is not activated.

Configuring controllers for an OpenFlow switch

Configuring controllers and main connections

An OpenFlow switch supports up to 8 controllers. However, the OpenFlow channel between the

OpenFlow switch and each controller can have only one main connection, which uses TCP or SSL. The
main connection must be reliable and processes control messages to complete tasks such as deploying

entries, obtaining data, and sending information.
To specify a controller for an OpenFlow switch and configure the main connection to the controller:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter OpenFlow instance
view.

openflow instance instance-id N/A

3.

Specify a controller and
configure the main connection

to the controller.

controller id address { ip
ip-address | ipv6 ipv6-address }

[ port port-number ] [ ssl

ssl-policy-name ]

By default, an OpenFlow instance
is not configured with any main
connection.

Setting the connection interruption mode

An OpenFlow switch is set to either of the following modes when it is disconnected from all controllers:

Secure—In this mode, the OpenFlow switch forwards traffic based on flow tables and does not
delete unexpired flow entries.

Standalone—The OpenFlow switch uses the normal forwarding process.

To set the connection interruption mode for an OpenFlow switch:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter OpenFlow instance
view.

openflow instance instance-id N/A

3.

Set the connection

interruption mode.

fail-open mode { secure |
standalone }

By default, the secure mode is
used.