Statistics of an openflow instance, Openflow features of an openflow instance, Openflow meter features of an openflow instance – H3C Technologies H3C Intelligent Management Center User Manual

Page 45: Openflow group features of an openflow instance, Deleting an openflow instance

Advertising
background image

35

Port Name—Name of the OpenFlow port. Ports with names beginning with OFPP represent

reserved ports that are defined by the OpenFlow standard.

MAC Address—MAC address of the OpenFlow port.

Port Status—Status of the OpenFlow port.

Current Speed (bps)—Current speed of the OpenFlow port, in bps.

Max Speed (bps)—Maximum speed of the OpenFlow port, in bps.

Statistics of an OpenFlow instance

OF Group—Number of groups in the OpenFlow instance. Click the link to view detailed information
about all groups. For more information, see "Viewing the group list."

OF Meter—Number of meters in the OpenFlow instance. Click the link to view detailed information
about all meters. For more information, see "Viewing the meter list."

OpenFlow features of an OpenFlow instance

Max Buffered Packets—Maximum number of packets that the OpenFlow instance can buffer before

it sends them to the controller.

Supported Flow Tables—Maximum number of flow tables the OpenFlow instance supports.

Traffic Object Statistics—Whether or not the OpenFlow instance supports traffic object statistics.

Flow Table Statistics—Whether or not the OpenFlow instance supports flow table statistics.

Port Statistics—Whether or not the OpenFlow instance supports port statistics.

Group Statistics—Whether or not the OpenFlow instance supports group statistics.

Queue Statistics—Whether or not the OpenFlow instance supports queue statistics.

OpenFlow meter features of an OpenFlow instance

Max Meters—Maximum number of meters the OpenFlow instance supports.

Types—Band types the OpenFlow instance supports.

Flags—Meter flags the OpenFlow instance supports.

Max Bands per Meter—Maximum number of bands that each meter supports in the OpenFlow
instance. Meters enable OpenFlow devices to support QoS.

Max Color Value—Maximum number of colors the OpenFlow instance supports. Colors are used
for the coloring-algorithm of QoS.

OpenFlow group features of an OpenFlow instance

Types—Group types the OpenFlow instance supports.

Capabilities—Group capabilities the OpenFlow instance supports.

Max Groups—Maximum number of groups the OpenFlow instance supports for each group type.

Actions—Actions the bucket in the group supports to configure.

Deleting an OpenFlow instance

In SDNM, one OpenFlow instance can be deleted at a time. To delete OpenFlow instances in batches,

see "

Deleting virtual OpenFlow devices

." Virtual OpenFlow devices are the same as OpenFlow

instances.
To delete an OpenFlow instance:

1.

Access the OpenFlow instance list page.