2040RDA-FR/16FR — Instruction Manual

Configuration and Adjustments

Settings Web Page Status Reporting

The following read-only status items are also reported on the Settings web
page:

Warning: Front Rear Mismatch

– when a 2040RDA-16FR module is installed

with a 2040RDA-FR-R rear module (only 8 outputs) this warning will
appear on the Settings page. The Status page will report the Internal
State condition as yellow (

Status Web Page on page 29

) and the front

edge FAULT LED will flash (

Table 1 on page 23

).

Note

This will not occur when a 2040RDA-FR is installed with a 2040RDA-16FR-R
rear module, but only 8 of the 16 BNC outputs will be active.

Opt Dev:

– the type of optic device installed will be reported as

No Dev

,

Error

,

Unknown Device

,

Tx-Tx 1310nm

(Dual Transmitter),

Tx-Rx 1310nm

(Input/Output Transceiver),

Opt Dev Status:

– the status of the optic device will be reported as

Pass

,

Fault

, or

N/A

.

Coax In:

– reports the presence of a valid signal on the Coax input as

Present

,

Not Present

, or

N/A

(not enabled).

Optic 1 In:

– reports the presence of a valid signal on the Optic 1 input as

Present

,

Not Present

, or

N/A

(not available or enabled).

Optic 2 In:

– reports the presence of a valid signal on the Optic 2 input as

Present

,

Not Present

, or

N/A

(not available or enabled).

Reclocker:

– reports whether the signal is

Locked

,

Unlocked

or

N/A

.

Auto Rate:

– reports the bit rate currently detected (

143M

,

177M

,

270M

,

360M

,

540M

,

or

1485M

),

N/A

, or

Unknown

.