41

Remote Configuration

Slot Config Web Page

Use
this
link

UUse the Slot Config web page shown in

Figure 23 on page 42

to perform

the following functions on the module.

Note

This Slot Config web page reflects the use of 8900NET (Net Card) software
version 4.3.0.

Locate Module

Selecting

Flash

from the

Locate Module

pulldown flashes the yellow COMM

and CONF LEDs on the front of the module so it can be located in the
frame.

Slot Identification

You may identify the module by typing a specific name in the

Name

field.

The assigned name is stored on the 8900NET module and travels with the
8900NET module if it is moved to another frame. Select

Default

to enter the

factory default module name.

An asset identification may be entered in the

Asset Tag

field. This will appear

on the module Status web page and in the NetConfig inventory report.

Slot Memory

T

he slot configuration for each media module is automatically polled and

refreshed periodically (about every 50 minutes) by the 8900NET module
when the

Always Slot Refresh

checkbox on the 8900NET Configuration web

page (with 4.3.0 software) and/or the

Restore upon Install

checkbox on any

media module Slot Config web page is selected.

When the

Restore upon Install

checkbox on any media module Slot Config

web page has been selected, the current configuration from that module is
saved in slot memory on the 8900NET module. This allows the current
module to be removed and when another module of the same part number,
and software version is installed, the configuration saved to the 8900NET
module will be downloaded to the installed module. The

Restore upon Install

checkbox must be selected before the current module with the saved con-
figuration is removed.

Note

Make sure all modules of the same model type are running the same software
version and have the same part number silk-screened on the printed circuit
board. Downloading a configuration to a module with a different software
version or part number can produce unexpected results.

If a different type of module is installed in this slot, a warning message will
state that the original module type has been replaced with another module
type. In this case, a

Clear

button will appear allowing you to clear the stored

configuration from the previous module.

Advertising