Tsl protocol version 3.1 – Grass Valley 8949SVM-LOC User Manual

Page 38

Advertising
background image

38

8949SVM-LOC/-UMD—Instruction Manual

TSL Protocol Version 3.1

TSL Protocol Version 3.1

The following section describes TSL protocol version 3.1 in

Table 4

and

Table 5

.

Table 4. Version 3.1 Byte Offsets and Functions

Byte Offset

Function

0

Unit ID

1

Tally Control

2-17

UMD Text

Table 5. 3.1 Protocol Description

Unit ID

Unit Level Addressing for Multicast Data

(Bit 7)

Must be 1

(Bit 6..0)

Unit addresses are in range 0...126. The value of 127 is taken to
address all units (to which the packets are delivered). Unit address
is controlled by the Multicast ID set through the paddle switch con-
trols.

Tally Control

(Bit 7)

Must be 0

(Bit 6)

Must be 0

(Bit 5..4)

Not used

(Bit 3)

Tally 4

Selecting both Tally 3 and Tally 4 is
undefined behavior

(Bit 2)

Tally 3

(Bit 1)

Tally 2

Selecting both Tally 1 and Tally 2 is
undefined behavior

(Bit 0)

Tally 1

Tallies are mapped as follows:

Tally 4

Right Green

0: Off; 1: On

Tally 3

Right Red

0: Off; 1: On

Tally 2

Left Green

0: Off; 1: On

Tally 1

Left Red

0: Off; 1: On

UMD Text

16 characters

UMD text characters includes the standard ASCII character set along with an
Extended Character set described in

Extended Character Set on page 37

.