Setting up gen lock with your control keypad – Grass Valley 1-CCD CameraMan Rev.D1 User Manual
Page 16
Page 13
Meet Your Camera Control Keypad
Setting Up Gen Lock with Your Control Keypad
Gen Lock Setup (without the overlay card)
The following procedure will enable you to adjust Gen Lock settings without the Gen Lock
Setup overlay card.
1. Press and hold down button numbers 0 and 8. After 2-3 seconds, you will hear
a beep.
2. Release the 0 and 8 buttons. The Gen Lock Setup menu appears.
To reset the menu items to the default values, press button number 1.
3. Press the up and down PAN/TILT arrows to move the arrow on-screen and to select
the item you want to change.
4. Press the left and right PAN/TILT arrows to change the value for the following
items:
Menu Item
Values
MODE
AUTO or INT (internal)
H-PHASE
-99° to +99°
SCFINE
-99° to +99°
5. To save your changes, press button number 2.
The SC-PHASE is set using Dip Switch number 2: DOWN = 150° and UP = 180°.
6. Press and hold 8 and 0 to exit.