Alarms

Each time a new error arises, an alarm can be heard (provided options for this have
been selected, see the

“Client Preferences”

section). Information messages are

indicated by blue icons. Error messages are red-colored. Warnings are
orange-colored.

To stop alarms, use the

toolbar button. All alarms will stop. Since alarms are

client dependent, stopping an alarm on one client will not stop it on the others.

Specific Messages view

Messages relative to a particular service or connector can be directly reached to view
the alarms concerning a selected service or connector. To do so, select a connector,
an input or a service, and select

Display Messages

from the contextual menu.

All messages are available in a daily log file that is located on the server. Files can be
found in the C:\Report\VideoServer folder.

Current Error State

To reach the current error state of an item (i.e. board, connector, service), right-click
it and select

Current error state

from the menu.

Error state window is displayed. It lists current errors (in

red

) and errors to

acknowledge (in

orange

). Listed errors are the following:

Listed Error

Meaning

Opening stream error

An input or output card connector cannot be used on the ASI
card or a network destination is unreachable.

Reading stream error

Error while reading data.

Writing stream error

Error chile writing data.

Initializing stream error

Error while initializing input or output on ASI board.

Starting stream error

Error starting board, input or output.

Synchronize error

Synchronization error on the stream.

Table coherence error

The PSI table content is not correct.